How should I connect my cat5 cable to connectors having an orange-green line? The Next CEO of Stack OverflowCan I use a junction box to splice together wires that are on a different circuit?Help connecting cat5e cables for home networkingHow can I run cables along a concrete wall?Which cable/conduit should I use to run a new 240 volt line for an oven?Run cat5e/coax parallel to power conduitWhat kind of wiring/service are these wires for and how do I test them to find out?How to set up home network w/ fiber from street & unterminated Cat5e in garageConnect to pre-wired Cat5e (no clear demarc point)Re-wire Cat5e RJ11 jacks to RJ45 ethernetWiring ethernet cable from AT&T fiber Modem to a specific room

"Eavesdropping" vs "Listen in on"

How should I connect my cat5 cable to connectors having an orange-green line?

Avoiding the "not like other girls" trope?

subequations: How to continue numbering within subequation?

The sum of any ten consecutive numbers from a fibonacci sequence is divisible by 11

How can I force the size of an int for debugging purposes?

My ex-girlfriend uses my Apple ID to login to her iPad, do I have to give her my Apple ID password to reset it?

How to find out why iTerm2 suddenly wants to access my Calendar?

Strange use of "whether ... than ..." in official text

Car headlights in a world without electricity

Plausibility of squid whales

DISTINCT column combination with permutations

Is it OK to decorate a log book cover?

Man transported from Alternate World into ours by a Neutrino Detector

Could a dragon use its wings to swim?

How to implement Comparable so it is consistent with identity-equality

How to avoid supervisors with prejudiced views?

Is a distribution that is normal, but highly skewed, considered Gaussian?

What happens if you break a law in another country outside of that country?

Is a bad practice make variations on power's tracks width in pcb?

Can I cast Thunderwave and be at the center of its bottom face, but not be affected by it?

Can Sri Krishna be called 'a person'?

What difference does it make matching a word with/without a trailing whitespace?

Does the Idaho Potato Commission associate potato skins with healthy eating?



How should I connect my cat5 cable to connectors having an orange-green line?



The Next CEO of Stack OverflowCan I use a junction box to splice together wires that are on a different circuit?Help connecting cat5e cables for home networkingHow can I run cables along a concrete wall?Which cable/conduit should I use to run a new 240 volt line for an oven?Run cat5e/coax parallel to power conduitWhat kind of wiring/service are these wires for and how do I test them to find out?How to set up home network w/ fiber from street & unterminated Cat5e in garageConnect to pre-wired Cat5e (no clear demarc point)Re-wire Cat5e RJ11 jacks to RJ45 ethernetWiring ethernet cable from AT&T fiber Modem to a specific room










1















I have some cat5 cables in my attic in need to splice . they have been up there for 10 to 15years so no sure if cat5e or cat5.



I'm looking at a tool-less connector on amazon, but the color coding has a orange-green line I do not see in my cable



enter image description here



enter image description here










share|improve this question



















  • 1





    Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

    – Ecnerwal
    1 hour ago















1















I have some cat5 cables in my attic in need to splice . they have been up there for 10 to 15years so no sure if cat5e or cat5.



I'm looking at a tool-less connector on amazon, but the color coding has a orange-green line I do not see in my cable



enter image description here



enter image description here










share|improve this question



















  • 1





    Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

    – Ecnerwal
    1 hour ago













1












1








1








I have some cat5 cables in my attic in need to splice . they have been up there for 10 to 15years so no sure if cat5e or cat5.



I'm looking at a tool-less connector on amazon, but the color coding has a orange-green line I do not see in my cable



enter image description here



enter image description here










share|improve this question
















I have some cat5 cables in my attic in need to splice . they have been up there for 10 to 15years so no sure if cat5e or cat5.



I'm looking at a tool-less connector on amazon, but the color coding has a orange-green line I do not see in my cable



enter image description here



enter image description here







wiring ethernet






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited 1 hour ago









manassehkatz

10.1k1337




10.1k1337










asked 2 hours ago









Hell.BentHell.Bent

1164




1164







  • 1





    Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

    – Ecnerwal
    1 hour ago












  • 1





    Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

    – Ecnerwal
    1 hour ago







1




1





Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

– Ecnerwal
1 hour ago





Note the faint text on the outer jacket of the cable. Examine that carefully and it will tell you (generally repeating every 2 or 3 feet) exactly what type of cable it is.)

– Ecnerwal
1 hour ago










1 Answer
1






active

oldest

votes


















4














That's not "orange/green", it is T568A vs. T568B



Cat 3/5/6 cabling comes in two "flavors" - T568A and T568B. They are functionally identical. The only question is the sequence - Blue/Orange/Green/Brown vs. Blue/Green/Orange/Brown. Most connectors & jacks include color-coding for both types, marked "A" and "B", so that you can mix & match parts from different brands and have everything work together. The electrons don't care about the insulation color.



I usually use T568B, but it really doesn't matter as long as you are consistent - i.e., both ends of each cable should (normally) be the same.



What does matter is the quality of the connection.



Each new cable type 3 -> 5 -> 5e -> 6 puts in new, more exacting requirements on the number of twists and other factors. So make sure any connectors, adapters, splices, etc. meet the requirements of the cable type you want to use. If you have Cat 6 everywhere except one segment is Cat 5e then you'll be fine with Cat 5e speeds but Cat 6 might not work, and you may have trouble figuring out why things aren't working right. So I would at a minimum use the same quality/specification for everything that is hidden - wall jacks, cable inside walls, splices in the attic, etc.






share|improve this answer

























    Your Answer








    StackExchange.ready(function()
    var channelOptions =
    tags: "".split(" "),
    id: "73"
    ;
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function()
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled)
    StackExchange.using("snippets", function()
    createEditor();
    );

    else
    createEditor();

    );

    function createEditor()
    StackExchange.prepareEditor(
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: false,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: null,
    bindNavPrevention: true,
    postfix: "",
    imageUploader:
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    ,
    noCode: true, onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    );



    );













    draft saved

    draft discarded


















    StackExchange.ready(
    function ()
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f161152%2fhow-should-i-connect-my-cat5-cable-to-connectors-having-an-orange-green-line%23new-answer', 'question_page');

    );

    Post as a guest















    Required, but never shown

























    1 Answer
    1






    active

    oldest

    votes








    1 Answer
    1






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    4














    That's not "orange/green", it is T568A vs. T568B



    Cat 3/5/6 cabling comes in two "flavors" - T568A and T568B. They are functionally identical. The only question is the sequence - Blue/Orange/Green/Brown vs. Blue/Green/Orange/Brown. Most connectors & jacks include color-coding for both types, marked "A" and "B", so that you can mix & match parts from different brands and have everything work together. The electrons don't care about the insulation color.



    I usually use T568B, but it really doesn't matter as long as you are consistent - i.e., both ends of each cable should (normally) be the same.



    What does matter is the quality of the connection.



    Each new cable type 3 -> 5 -> 5e -> 6 puts in new, more exacting requirements on the number of twists and other factors. So make sure any connectors, adapters, splices, etc. meet the requirements of the cable type you want to use. If you have Cat 6 everywhere except one segment is Cat 5e then you'll be fine with Cat 5e speeds but Cat 6 might not work, and you may have trouble figuring out why things aren't working right. So I would at a minimum use the same quality/specification for everything that is hidden - wall jacks, cable inside walls, splices in the attic, etc.






    share|improve this answer





























      4














      That's not "orange/green", it is T568A vs. T568B



      Cat 3/5/6 cabling comes in two "flavors" - T568A and T568B. They are functionally identical. The only question is the sequence - Blue/Orange/Green/Brown vs. Blue/Green/Orange/Brown. Most connectors & jacks include color-coding for both types, marked "A" and "B", so that you can mix & match parts from different brands and have everything work together. The electrons don't care about the insulation color.



      I usually use T568B, but it really doesn't matter as long as you are consistent - i.e., both ends of each cable should (normally) be the same.



      What does matter is the quality of the connection.



      Each new cable type 3 -> 5 -> 5e -> 6 puts in new, more exacting requirements on the number of twists and other factors. So make sure any connectors, adapters, splices, etc. meet the requirements of the cable type you want to use. If you have Cat 6 everywhere except one segment is Cat 5e then you'll be fine with Cat 5e speeds but Cat 6 might not work, and you may have trouble figuring out why things aren't working right. So I would at a minimum use the same quality/specification for everything that is hidden - wall jacks, cable inside walls, splices in the attic, etc.






      share|improve this answer



























        4












        4








        4







        That's not "orange/green", it is T568A vs. T568B



        Cat 3/5/6 cabling comes in two "flavors" - T568A and T568B. They are functionally identical. The only question is the sequence - Blue/Orange/Green/Brown vs. Blue/Green/Orange/Brown. Most connectors & jacks include color-coding for both types, marked "A" and "B", so that you can mix & match parts from different brands and have everything work together. The electrons don't care about the insulation color.



        I usually use T568B, but it really doesn't matter as long as you are consistent - i.e., both ends of each cable should (normally) be the same.



        What does matter is the quality of the connection.



        Each new cable type 3 -> 5 -> 5e -> 6 puts in new, more exacting requirements on the number of twists and other factors. So make sure any connectors, adapters, splices, etc. meet the requirements of the cable type you want to use. If you have Cat 6 everywhere except one segment is Cat 5e then you'll be fine with Cat 5e speeds but Cat 6 might not work, and you may have trouble figuring out why things aren't working right. So I would at a minimum use the same quality/specification for everything that is hidden - wall jacks, cable inside walls, splices in the attic, etc.






        share|improve this answer















        That's not "orange/green", it is T568A vs. T568B



        Cat 3/5/6 cabling comes in two "flavors" - T568A and T568B. They are functionally identical. The only question is the sequence - Blue/Orange/Green/Brown vs. Blue/Green/Orange/Brown. Most connectors & jacks include color-coding for both types, marked "A" and "B", so that you can mix & match parts from different brands and have everything work together. The electrons don't care about the insulation color.



        I usually use T568B, but it really doesn't matter as long as you are consistent - i.e., both ends of each cable should (normally) be the same.



        What does matter is the quality of the connection.



        Each new cable type 3 -> 5 -> 5e -> 6 puts in new, more exacting requirements on the number of twists and other factors. So make sure any connectors, adapters, splices, etc. meet the requirements of the cable type you want to use. If you have Cat 6 everywhere except one segment is Cat 5e then you'll be fine with Cat 5e speeds but Cat 6 might not work, and you may have trouble figuring out why things aren't working right. So I would at a minimum use the same quality/specification for everything that is hidden - wall jacks, cable inside walls, splices in the attic, etc.







        share|improve this answer














        share|improve this answer



        share|improve this answer








        edited 2 hours ago

























        answered 2 hours ago









        manassehkatzmanassehkatz

        10.1k1337




        10.1k1337



























            draft saved

            draft discarded
















































            Thanks for contributing an answer to Home Improvement Stack Exchange!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid


            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.

            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function ()
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f161152%2fhow-should-i-connect-my-cat5-cable-to-connectors-having-an-orange-green-line%23new-answer', 'question_page');

            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            名間水力發電廠 目录 沿革 設施 鄰近設施 註釋 外部連結 导航菜单23°50′10″N 120°42′41″E / 23.83611°N 120.71139°E / 23.83611; 120.7113923°50′10″N 120°42′41″E / 23.83611°N 120.71139°E / 23.83611; 120.71139計畫概要原始内容臺灣第一座BOT 模式開發的水力發電廠-名間水力電廠名間水力發電廠 水利署首件BOT案原始内容《小檔案》名間電廠 首座BOT水力發電廠原始内容名間電廠BOT - 經濟部水利署中區水資源局

            格濟夫卡 參考資料 导航菜单51°3′40″N 34°2′21″E / 51.06111°N 34.03917°E / 51.06111; 34.03917ГезівкаПогода в селі 编辑或修订