Converting a variable frequency to TTL HIGH and LOW levels, based on a fixed (possible non-fixed?) frequencySwitching relay with a PNP and TTL levelsMC34063A: Why am I overclocking this chip?Changing Low Frequency to High FrequencyDebouncing a TTL Photodiode DetectorHow to make a AC current source of variable low frequency and variable low amplitudeOp-amp for pulse width modulation, 5v single rail supplyConverting varying frequency and duty cycle to varying frequency fixed duty cycleState Variable Filter - Unexpected High Frequency BehaviorMulti PWM switch with mosfetAmplification of sinusoidal signal from filter circuit

As a new Ubuntu desktop 18.04 LTS user, do I need to use ufw for a firewall or is iptables sufficient?

Shortcut for setting origin to vertex

Is it insecure to send a password in a `curl` command?

Most cost effective thermostat setting: consistent temperature vs. lowest temperature possible

What are substitutions for coconut in curry?

I am confused as to how the inverse of a certain function is found.

What is the Japanese sound word for the clinking of money?

Do I need to be arrogant to get ahead?

Is there a hypothetical scenario that would make Earth uninhabitable for humans, but not for (the majority of) other animals?

Meme-controlled people

This word with a lot of past tenses

Simplify an interface for flexibly applying rules to periods of time

Have the tides ever turned twice on any open problem?

Converting a variable frequency to TTL HIGH and LOW levels, based on a fixed (possible non-fixed?) frequency

What options are left, if Britain cannot decide?

Welcoming 2019 Pi day: How to draw the letter π?

Brexit - No Deal Rejection

My adviser wants to be the first author

How to make healing in an exploration game interesting

What exactly is this small puffer fish doing and how did it manage to accomplish such a feat?

What is the adequate fee for a reveal operation?

A single argument pattern definition applies to multiple-argument patterns?

What is "focus distance lower/upper" and how is it different from depth of field?

Recruiter wants very extensive technical details about all of my previous work



Converting a variable frequency to TTL HIGH and LOW levels, based on a fixed (possible non-fixed?) frequency


Switching relay with a PNP and TTL levelsMC34063A: Why am I overclocking this chip?Changing Low Frequency to High FrequencyDebouncing a TTL Photodiode DetectorHow to make a AC current source of variable low frequency and variable low amplitudeOp-amp for pulse width modulation, 5v single rail supplyConverting varying frequency and duty cycle to varying frequency fixed duty cycleState Variable Filter - Unexpected High Frequency BehaviorMulti PWM switch with mosfetAmplification of sinusoidal signal from filter circuit













1












$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    1 hour ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    1 hour ago















1












$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    1 hour ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    1 hour ago













1












1








1





$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$




I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?







arduino operational-amplifier frequency ttl conversion






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited 3 mins ago









SamGibson

11.4k41738




11.4k41738










asked 2 hours ago









sina rahbarisina rahbari

83




83











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    1 hour ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    1 hour ago
















  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    1 hour ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    1 hour ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    1 hour ago















$begingroup$
High pass filter?
$endgroup$
– Linkyyy
1 hour ago




$begingroup$
High pass filter?
$endgroup$
– Linkyyy
1 hour ago












$begingroup$
nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
$endgroup$
– sina rahbari
1 hour ago




$begingroup$
nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
$endgroup$
– sina rahbari
1 hour ago












$begingroup$
on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
$endgroup$
– sina rahbari
1 hour ago




$begingroup$
on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
$endgroup$
– sina rahbari
1 hour ago












$begingroup$
A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
$endgroup$
– Hearth
1 hour ago




$begingroup$
A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
$endgroup$
– Hearth
1 hour ago










2 Answers
2






active

oldest

votes


















1












$begingroup$

One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






share|improve this answer









$endgroup$




















    1












    $begingroup$

    You have multiple alternatives, each one of them with different trade offs.



    • The conceptually simplest and most precise one, would be to use a pulse counter.

    This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



    • Translate that same idea to the analog domain. Using a ramp as the “counter”.

    Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



    • Use a retriggerable monostable. With the duration being the comparison value.

    A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



    • use a filter slope and a peak detector (just as some cheap FM radios)

    A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



    • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

    By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



    Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



    If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






    share|improve this answer









    $endgroup$












      Your Answer





      StackExchange.ifUsing("editor", function ()
      return StackExchange.using("mathjaxEditing", function ()
      StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix)
      StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
      );
      );
      , "mathjax-editing");

      StackExchange.ifUsing("editor", function ()
      return StackExchange.using("schematics", function ()
      StackExchange.schematics.init();
      );
      , "cicuitlab");

      StackExchange.ready(function()
      var channelOptions =
      tags: "".split(" "),
      id: "135"
      ;
      initTagRenderer("".split(" "), "".split(" "), channelOptions);

      StackExchange.using("externalEditor", function()
      // Have to fire editor after snippets, if snippets enabled
      if (StackExchange.settings.snippets.snippetsEnabled)
      StackExchange.using("snippets", function()
      createEditor();
      );

      else
      createEditor();

      );

      function createEditor()
      StackExchange.prepareEditor(
      heartbeatType: 'answer',
      autoActivateHeartbeat: false,
      convertImagesToLinks: false,
      noModals: true,
      showLowRepImageUploadWarning: true,
      reputationToPostImages: null,
      bindNavPrevention: true,
      postfix: "",
      imageUploader:
      brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
      contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
      allowUrls: true
      ,
      onDemand: true,
      discardSelector: ".discard-answer"
      ,immediatelyShowMarkdownHelp:true
      );



      );













      draft saved

      draft discarded


















      StackExchange.ready(
      function ()
      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f427566%2fconverting-a-variable-frequency-to-ttl-high-and-low-levels-based-on-a-fixed-po%23new-answer', 'question_page');

      );

      Post as a guest















      Required, but never shown

























      2 Answers
      2






      active

      oldest

      votes








      2 Answers
      2






      active

      oldest

      votes









      active

      oldest

      votes






      active

      oldest

      votes









      1












      $begingroup$

      One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



      The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



      You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






      share|improve this answer









      $endgroup$

















        1












        $begingroup$

        One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



        The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



        You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






        share|improve this answer









        $endgroup$















          1












          1








          1





          $begingroup$

          One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



          The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



          You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






          share|improve this answer









          $endgroup$



          One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



          The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



          You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.







          share|improve this answer












          share|improve this answer



          share|improve this answer










          answered 1 hour ago









          Michael KarasMichael Karas

          44.6k348103




          44.6k348103























              1












              $begingroup$

              You have multiple alternatives, each one of them with different trade offs.



              • The conceptually simplest and most precise one, would be to use a pulse counter.

              This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



              • Translate that same idea to the analog domain. Using a ramp as the “counter”.

              Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



              • Use a retriggerable monostable. With the duration being the comparison value.

              A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



              • use a filter slope and a peak detector (just as some cheap FM radios)

              A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



              • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

              By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



              Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



              If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






              share|improve this answer









              $endgroup$

















                1












                $begingroup$

                You have multiple alternatives, each one of them with different trade offs.



                • The conceptually simplest and most precise one, would be to use a pulse counter.

                This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                • Use a retriggerable monostable. With the duration being the comparison value.

                A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                • use a filter slope and a peak detector (just as some cheap FM radios)

                A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






                share|improve this answer









                $endgroup$















                  1












                  1








                  1





                  $begingroup$

                  You have multiple alternatives, each one of them with different trade offs.



                  • The conceptually simplest and most precise one, would be to use a pulse counter.

                  This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                  • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                  Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                  • Use a retriggerable monostable. With the duration being the comparison value.

                  A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                  • use a filter slope and a peak detector (just as some cheap FM radios)

                  A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                  • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                  By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                  Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                  If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






                  share|improve this answer









                  $endgroup$



                  You have multiple alternatives, each one of them with different trade offs.



                  • The conceptually simplest and most precise one, would be to use a pulse counter.

                  This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                  • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                  Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                  • Use a retriggerable monostable. With the duration being the comparison value.

                  A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                  • use a filter slope and a peak detector (just as some cheap FM radios)

                  A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                  • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                  By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                  Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                  If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.







                  share|improve this answer












                  share|improve this answer



                  share|improve this answer










                  answered 39 mins ago









                  Edgar BrownEdgar Brown

                  6,4372735




                  6,4372735



























                      draft saved

                      draft discarded
















































                      Thanks for contributing an answer to Electrical Engineering Stack Exchange!


                      • Please be sure to answer the question. Provide details and share your research!

                      But avoid


                      • Asking for help, clarification, or responding to other answers.

                      • Making statements based on opinion; back them up with references or personal experience.

                      Use MathJax to format equations. MathJax reference.


                      To learn more, see our tips on writing great answers.




                      draft saved


                      draft discarded














                      StackExchange.ready(
                      function ()
                      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f427566%2fconverting-a-variable-frequency-to-ttl-high-and-low-levels-based-on-a-fixed-po%23new-answer', 'question_page');

                      );

                      Post as a guest















                      Required, but never shown





















































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown

































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown







                      Popular posts from this blog

                      名間水力發電廠 目录 沿革 設施 鄰近設施 註釋 外部連結 导航菜单23°50′10″N 120°42′41″E / 23.83611°N 120.71139°E / 23.83611; 120.7113923°50′10″N 120°42′41″E / 23.83611°N 120.71139°E / 23.83611; 120.71139計畫概要原始内容臺灣第一座BOT 模式開發的水力發電廠-名間水力電廠名間水力發電廠 水利署首件BOT案原始内容《小檔案》名間電廠 首座BOT水力發電廠原始内容名間電廠BOT - 經濟部水利署中區水資源局

                      格濟夫卡 參考資料 导航菜单51°3′40″N 34°2′21″E / 51.06111°N 34.03917°E / 51.06111; 34.03917ГезівкаПогода в селі 编辑或修订